DCI - Tabletop Handpiece Flush System Provides Regulated & Filtered Air For Cleaning Aiding International - 4060
- VendorDCI International
DCI - Tabletop Handpiece Flush System Provides Regulated & Filtered Air For Cleaning Aiding International - 4060
- VendorDCI International
$170.05
- For high-speed handpieces only; compact tabletop model
- 35-micron filtered air; adjustable pressure gauge included
- Purges air and water coolant lines; no foot control required
- Bottle collects excess lubricant; easy-to-clean surfaces
- Requires 80 PSI, 1/4" air hook-up; adapter sold separately
- Quantity: 1 per Each
DCI International Tabletop Handpiece Flush System is used for cleaning and lubricating high-speed dental handpieces between patient appointments and after autoclave sterilization cycles as part of a routine handpiece maintenance program, providing a compact tabletop instrument that delivers regulated, filtered air through the handpiece's internal turbine and air bearing channels to purge residual debris, aerosol, and moisture from the handpiece's internal air and water coolant lines while simultaneously assisting the penetration of handpiece lubricant into the internal turbine bearings and air-driven components to reduce friction and extend the handpiece's operational service life between professional servicing events. The system provides regulated and filtered air through its adjustable pressure regulator with an easy-to-read gauge, allowing the dental assistant or clinician to set the air pressure to the appropriate level for the handpiece being maintained and monitor the applied pressure during the flush and lubrication cycle without guesswork, and the 35-micron inline air filter removes particulate contamination from the incoming air supply before it contacts the handpiece's internal components during the cleaning cycle.
Purging the handpiece's air and water coolant lines as part of the post-sterilization maintenance step helps remove moisture that accumulates within the handpiece during autoclave sterilization from condensing steam, restoring dry air flow through the coolant lines before the handpiece is returned to clinical service. Dental assistants, sterilization coordinators, and practice managers who maintain high-speed dental handpiece inventories and perform handpiece cleaning and lubrication as part of a structured after-sterilization handpiece maintenance protocol find DCI International Tabletop Handpiece Flush System the compact 35-micron filtered adjustable-pressure post-autoclave handpiece flush and lubrication maintenance system for their active handpiece maintenance program.
?
The DCI International Tabletop Handpiece Flush System is sold without a handpiece adapter, and requires a handpiece-specific adapter to connect the flush system to the high-speed handpiece being maintained. Adapters are sold separately and must be selected to match the specific handpiece brand in use: KAVO handpieces require adapter PN 4086, Lares requires PN 4090, Midwest 4 or 5 hole requires PN 4088, Midwest XGT and Stylus with Swivel requires PN 4111, NSK requires PN 4084, Star requires PN 4089, and W&H requires PN 4096.
The system requires an 80 PSI compressed air supply with a 1/4-inch tubing hook-up at the installation location. The integrated bottle at the system base collects the excess lubricant that purges from the handpiece during the flush cycle, preventing lubricant from contaminating the flush system's air circuit and the work surface below the unit during the maintenance procedure. The system has a 1-year warranty.
?
DCI International Tabletop Handpiece Flush System works through its compact tabletop housing that contains the 35-micron inlet air filter, adjustable pressure regulator, pressure gauge, and handpiece connection port, where compressed air at 80 PSI enters the unit from the 1/4-inch air hook-up, passes through the 35-micron filter to remove inlet air particulates, and then flows through the adjustable regulator to deliver clean, regulated air at the selected pressure through the handpiece adapter into the handpiece's internal air channels during the flush cycle.
No foot control is required for system operation, with the flush cycle activated directly at the unit, making the tabletop system a self-contained benchtop maintenance station that does not require integration with the dental unit's foot control or air supply beyond the dedicated 1/4-inch 80 PSI compressed air connection at the sterilization area.
?
Dental assistants who maintain handpiece inventories across multiple operatory positions and process handpieces through the clean, lubricate, and autoclave cycle after each patient use find the DCI flush system provides the regulated flush and lubrication step between clinical use and autoclave processing, or the post-autoclave relubrication step after sterilization, as part of a complete handpiece maintenance protocol. Practices that hand-lubricate handpieces by manually spraying lubricant into the handpiece head find the tabletop flush system provides a more consistent and complete internal lubrication cycle by delivering regulated air pressure through the handpiece's internal channels during the lubrication event.
?
DCI International Tabletop Handpiece Flush System gives dental practices a compact, self-contained, 35-micron filtered, adjustable-pressure tabletop handpiece maintenance unit that purges air and water coolant lines, assists handpiece lubrication, collects excess lubricant, aids post-autoclave relubrication, and requires no foot control, for high-speed handpieces only with brand-specific adapter sold separately, requiring 80 PSI at a 1/4-inch air connection, with 1-year warranty, 1 per pack.