MetriCide OPA Plus Solution Test Strips ? 100 test strips per bottle. To test
- VendorUS Metrex
MetriCide OPA Plus Solution Test Strips ? 100 test strips per bottle. To test
- VendorUS Metrex
$130.09
- Dip-and-read procedure gives reliable results in 60 seconds
- Tests MetriCide OPA Plus solution concentration (typically 0.3%)
- Ensures disinfectant potency for safety and compliance
- Critical for monitoring the solution's 21 or 28 day use life
- Quantity: 100 strips per bottle
The Metrex Research offers MetriCide OPA Plus Solution Test Strips are essential monitoring tools designed for validating the Minimum Effective Concentration (MEC) of the high-level disinfectant, MetriCide OPA Plus Solution. This is a crucial step in reprocessing heat-sensitive, semi-critical medical devices, ensuring compliance with reprocessing guidelines and patient safety standards.
Each bottle contains 100 disposable test strips, providing ample supply for consistent, accurate testing within the required 21 or 28-day usage life of the OPA solution, depending on the specific product formulation being monitored. The simple, dip-and-read procedure provides results in seconds, making it a highly efficient part of the sterilization workflow. The test strips are formulated to indicate when the OPA solution has dropped below its required MEC threshold, which is typically 0.3%.
The strips are simple to use, requiring only a brief dip into the solution followed by a short read time, typically just 60 seconds, to yield a reliable pass/fail result. If you are searching for the best MetriCide OPA Plus Solution Test Strips then this product, which provides fast, reliable, and easy-to-read verification of the solution's potency, is best for you. Regular testing prevents the use of compromised disinfectant, safeguarding against potential healthcare-associated infections.
The test is performed by simply dipping the strip into the solution for a specified time, followed by a brief wait to observe the color change; a distinct color on the test pad indicates the solution is active and safe for use, while a lack of color indicates the solution must be discarded and replaced. Accurate measurement and documentation of the MEC are non-negotiable for adhering to regulatory standards, and these strips are engineered for maximum reliability, providing peace of mind to central sterile processing departments and endoscopy suites. This commitment to accuracy ensures that every reprocessing cycle achieves the necessary level of microbial inactivation.